VERIFICATION EXAMPLES FOR SCADA Pro

Software Verification Examples for SCADA Pro 9 A2.2. Plane Steel Frame Problem Description A one-story plane frame subjected to vertical or horizontal loading is examined (Figure A2.2.1). Geometry, Properties and Loads The span opening is 7.0m and height of vertical members (columns) is 5.0m. The cross sections of columns and horizontal members are IPE-450 and IPE-330, respectively. Modulus of elasticity of the material is 210GPa and Poisson ratio is 0.30. Footing’s dimensions are 150cmx150cmx50cm for each column and ground stiffness is 100kPa/cm. Two cases of loading are studied. According to the first one, self-weight is taken into account (ε s =78.5kN/m 3 ) and horizontal member is subjected to distributed vertical load of 10kN/m (Load Case 1). In the second case, self weight is ignored and column AB is subjected to a distributed horizontal load of 5kN/m (Load Case 2). Stiffness of elastic support k y = 22500kN/m k φx =r φz = 4219kNm/rad Load Case 1 Load Case 2 Figure A2.2.1. Plane Steel Frame subjected to vertical or horizontal loading.

RkJQdWJsaXNoZXIy NTIwNzc=