VERIFICATION EXAMPLES FOR SCADA Pro

Software Verification Examples for SCADA Pro 57 (maxMz: 912.3kNm/-405.5kNm) Case1: SAP2000 (maxMz: 911.9kNm/-406.3kNm) Case1: ScadaPro Figure B2.4.4. Bending moments of the beam for b h 1.0m = (Case1). Computer Files The project files for this example are “B4_H50”, “B4_H100”, “B4_H150”, “B4_H200”. These files are provided as part of the ScadaPro installation. Conclusion The result comparison reflects acceptable agreement between ScadaPro software and results obtained from SAP2000, Nastran and the structural model presented by Sapountzakis and Mokos in [18].

RkJQdWJsaXNoZXIy NTIwNzc=