VERIFICATION EXAMPLES FOR SCADA Pro

Software Verification Examples for SCADA Pro 52 Table B2.3.1. Comparison of Results for Case 1 (Comb2). max Reinforcement (cm 2 /m) - ScadaPro Case 1 “Markus Tables” at the span of individual plate 1.88 at the support of individual plate 3.39 Case 2 “FEM” at the span of individual plate 1.68 at the support of individual plate 2.55 Computer Files The project files for this example are “B3_C1”, “B3_C2. These files are provided as part of the ScadaPro installation. Conclusion The result comparison reflects acceptable agreement between ScadaPro software and results obtained from Sofistik.