MODEL CHECKS & SIZING MESSAGES

SCADA Pro - Controls & Messages 2 MODEL CHECKS NUMBER REASONS error1001 The mathematical model of the vector has not been created or the member of the given beam has been deleted. Error1002 The mathematical model of the vector has not been created or the member of the given pole has been deleted. Error1003 The start and/or end node does not exist (may have been deleted). The member must be re-entered. Error3001 Warning for loads placed from bottom to top. If they are intentionally inserted in this way, the message is ignored. error3002 Warning message for members that have not received loads from plate reactions even though there are plate or plates that have that member as a limit. Error3003 There is a general problem with this particular plate. It needs to deleted and re-inserted. Error1678 The correct positioning direction of the poles is always from the bottom to top. The message means that the pole is positioned in the top-down direction. The error can be corrected by swapping the start and end nodes (the start node becomes the end node and the end node becomes the start node) of the pole bar. Error3013 The correct positioning direction of the beams is from left to right and from top to bottom. For the poles the correct direction is from bottom to top. The message comes out when some elements are not placed according to the above convention. The message is corrected by using the "Redefine Face" command. Error1008 At the junction number ... located at level ... there is no no member and obviously has no reason to exist and should be