MODEL CHECKS & SIZING MESSAGES
SCADA Pro - Controls & Messages 10 CONNECTING BEAMS: EX: • Beam 3: The thickness b= 180mm is less than 250mm. • Beam 3: The height h= 300mm is less than 400mm (ECOS 18.6.3) - For number of floors up to 3. • Beam 3: The height h= 300mm is less than 600mm (ECOS 18.6.3) - For number of floors from 4 and above. EC8 - CPM: • Beam 3: The thickness b= 180mm is less than 250mm. (EC8-1, 5.8.2(3)) • Beam 3: The height h= 300mm is less than 400mm (EC8-1, 5.8.2(3)) - For number of floors up to 3. • Beam 3: The height h= 300mm is less than 500mm (EC8-1, 5.8.2(3)) - For number of floors from 4 and above. EC8 - CIP: • Beam 3: The thickness b= 180mm is less than 250mm. (EC8-1, 5.8.2(3)) • Beam 3: The height h= 300mm is less than 400mm (EC8-1, 5.8.2(3)) - For number of floors up to 3. • Beam 3: The height h= 300mm is less than 500mm (EC8-1, 5.8.2(3)) - For number of floors from 4 and above.