B. COLUMN REINFORCEMENT DETAILS
73 CHAPTER B: COLUMN REINFORCEMENT DETAILS • You define the Material of • Select the desired Performance Level and Accessibility A, B or C for inelastic analysis ***** for the elastic analyses of CAN.EPE • In the Laminations field, you set the height and thickness of the laminations as well as the distance between them and the anchor length. • In the Angular Dimensions field, you specify the dimension of the angular plate, which is assumed to be isosceles, and its thickness. • By selecting the Checks button, the program calculates and displays the results. At the beginning of the checks, the bending capacity check and the shear capacity check of the concrete are shown. Then appear the shear test of the reinforced element.