B. COLUMN REINFORCEMENT DETAILS
41 CHAPTER B: COLUMN REINFORCEMENT DETAILS OBSERVATIONS: You also have the possibility to intervene in this table and change the diameter φ, the distance s or the number of segments n. With the command enabled the changes you make directly in the table are taken into account in the recheck. If you do not activate then for the recheck will take into account the original values, i.e. those that come automatically from the editor with the Auto option. . select the During the shear recheck, the program calculates new fastener spacing based on the new fastener diameter and the new number of segments. The procedure is as follows: From the initial sizing a required Asw/s of fasteners in the y and z directions has been derived for the critical and non-critical length. A total of 6 values. So, based on the new shape of the fastener and the new diameter, the program starts from the maximum distances defined by the regulation and starts an iterative procedure in order for the resulting Asw/s to be greater than the required one. The required value is given in brackets. The results are displayed in the box and divided by: