B. COLUMN REINFORCEMENT DETAILS

25 CHAPTER B: COLUMN REINFORCEMENT DETAILS Initial Diameter indicates the initial value of the selected diameter which is the same at the beginning and end of the rod. In Residual strength the default values are zero. The user is asked to set the value of the corrosion-residual diameter at the beginning and end of the bar. By selecting , these prices will will be applied to all the main bars of the selected element that have the same diameter, and will also change their colour to yellow to easily identify the bars where the corrosion has been applied. By selecting , these values will be applied to the specific bar.