8B. ANALYSIS PART 2

CHAPTER 8B 'ANALYSIS' 22 Extent of Damage The γsd factor is automatically calculated based on the corresponding option, The value 0 in the field means that the coefficient will take the value based on table .4.2. of the EIA. If you want your own value, enter a number and it will be added up to the value provided by the table. Calculations are made based on the resulting sum. Where more precise data are not available, cSd values according to following Table may be used. Table S 4.2: Values of the cSd coefficient Intense and extensive damage and/or interventions Light and localised damage and/or interventions Without damage and without interventions γSd =1,20 γSd =1,10 γSd = 1,00 See. See also Annex 7D on damage and deterioration. Then, select the command FRAME The EIR provides a minimum tolerable target based on the building's significance category based on the table below: