8B. ANALYSIS PART 2

CHAPTER 8B 'ANALYSIS' 126 All the above graphs are per distribution (Orthogonal, Triangular) and per seismic combination. So by selecting a distribution type and a seismic combination, in the list the steps of the specific inelastic analysis are displayed and for each step the cutting force Vb(kN) and the corresponding minimum load factor (λ) are shown. The corresponding point on the capacity curve is also shown in pink. At the bottom of the window the selection of the key is necessary to create the necessary prints and controls and to update them after possible changes (e.g. bilinearization method, change of spectra, change of parameters, etc.). the selection of the key displays the file containing the lists with : • Displacements and Junction Rotations for all junctions per direction • Intensive Member sizes at the beginning and end of each member • Active stiffnesses for each Pillar and each Beam the selection of the key displays the torque-torque diagram of the member which is shown by member (start - end) and by direction.