6. SLABS

CHAPTER 6 "SLABS" 19 2.6.3 Edit to modify the thickness of the plates specified with the previous commands. Select the command and in the dialog box: , enter the new value for the thickness, "OK" and then select the plates that will get this new thickness. The new thickness is indicated in the plate indicator symbol. 2.6.4 Minimum thickness if with the edit command, you change the "Minimum" thickness and give a larger value, then the "Minimum Thickness" command will reset the original value of the thickness of the selected plate. ATTENTION: In case the design is based on EURODATA , then the Final Thickness of the slab will be obtained after the Deformation Check . OBSERVATION: In the new version of SCADA Pro, the deformation control of the plates has been added. The deformation check is based on 7.4.2 and 7.4.3 of EC2 and is presented at the end of the results of each plate and if the scenario is not ECOS. The results of the two tests are shown separately. In the first check a minimum proposed thickness is obtained, but it cannot be proposed in the initial identification of the plate because its calculation requires the reinforcements. In the calculation of the first check, no intensive quantities are used, while the second check is carried out with the functional combination(s). OBSERVATION: In case of Insufficiency , the user should modify the original thickness, using the Edit command, and set in its place the Preferred minimum thickness hs (mm).