5. TOOLS
CHAPTER 5 "TOOLS" 34 The results apply to all nodes and for each node are listed: - The number of the node and then and per direction the ratio of the strength moments and the corresponding result are indicated. - The word error in front of the message is only displayed when one or both of the two reasons are less than 1.3. OBSERVATION: When even one member that exists on the node is category 4, the check is not performed and the following informational message is displayed: "There was no satisfactory audit. There are category 4 members." Clicking on a line turns the corresponding node in the vector model red. Because the ratios for both directions always occur when no beams occur in one direction, the denominator of the fraction becomes 0 and the ratio becomes 0, but obviously, in that direction there is no problem. Regarding the y-y and z-z directions, these refer (as in the concrete content material) to the local axes of the column ending at the node. For example, at the following node inside the red circle:
Made with FlippingBook