11. FORMWORK
CHAPTER 11 'FORMWORK' 38 If you ask for "Correction" again and activate the "Correction" button again, you , then the limits will appear again. This is only true in those cases where there were drawn boundaries and they were removed by the procedure described above. NO ALTERNATIVE WAY OF INTRODUCING BOUNDARIES. β. Total removal of the boundaries from all the plates designed 1. From the "PARAMETERS" command list, activate the "Plate faces" command . 2. In the dialog box that opens, click with the mouse on to remove the inside indication from the field and on under the number fields (to the right of "Limits") to display the inside indication. This way you instruct the program not to draw boundaries and to update all the already drawn plates with this option. Pressing on the button closes the dialog box and leaves the drawn boundaries from all the existing plates. If you re-enter the dialog box and check and the box to the right of it, the boundaries will be redrawn. This only applies to those cases where there were designed boundaries and they were left using the process described above. NO ALTERNATIVE WAY TO IMPORT BOUNDARIES. Fixed Columns: to enter in your design "Fixed Columns", (circles), "Filled" or not, depending on whether the corresponding option in "Parameters >>" is enabled. Pillars". The Pillar Stands introduced in this way are design entities. If, for example, a substructure already has a fixed point, it will not be deleted if you design a new one with the above command. Deleting Fixed Subpillars is done with the corresponding command from the "OPTIONS" option list.