CHAPTER 10D 'DIMENSIONING' 6 1.2 New masonry building (EC6) After the process is complete, select the command The Masonry Inspection according Eurocode 6 includes 6+1 checks: 1. In-plane bend check (user choice whether to perform) 2. Out-of-plane bending test parallel to the horizontal joint 3. Out-of-plane bending test perpendicular to the horizontal joint 4. Control in shear 5. Control on vertical loads, top 6. Control on vertical loads, medium 7. Control on vertical loads, base 8. The above 7 proficiency checks are defined for each wall or each wall section, depending on the separation defined by the user. 9. The above 7 adequacy checks exclude buildings that meet requirements to qualify as " Simple ". In the dialog box that opens, you are asked to specify the wall sections to perform the required checks: