10D. DIMENSIONING PART 4/4

CHAPTER 10D 'DIMENSIONING' 50 There are some lintels that fail in tension. Until now in SCADA Pro if an element failed in tension no further check was done. With the addition of the ability to reinforce in tension this criterion has changed and if tensile reinforcement is sufficient, as shown below all other checks are now performed. IMPORTANT OBSERVATION. It should be clarified that in SCADA Pro until now, when a tensile stress occurred, the combination with the corresponding worst tensile axial (positive) was indicated. In the new version of SCADA Pro, when a tensile stress occurs even in a combination, the designation is indicated in the corresponding field. However, the combination number and the corresponding line items do not belong to the tensile combination but to the combination that gives the worst ratio in the in-plane adequacy check (it is the check below).