10D. DIMENSIONING PART 4/4
CHAPTER 10D 'DIMENSIONING' 44 Then press the "Checks" button again and check the results obtained after inserting the grid. You can repeat the process. The program checks each time taking into account the last characteristics you set. 2.2.7 Reinforcement with metal rods In SCADA Pro have been integrated the reinforcements with metal rods in load-bearing masonry beams and is now automatically checked in tension in case the above reinforcement with metal rods has been placed and whether a concrete jacket (one-sided or two-sided) has been placed. • Bending out of plane about the horizontal axis. Tensile pickup.
Made with FlippingBook
RkJQdWJsaXNoZXIy NTIwNzc=