10D. DIMENSIONING PART 4/4
CHAPTER 10D 'DIMENSIONING' 26 2.2.1 Incorporation of the provisions of the CPR SCADA Pro offers the possibility to evaluate the masonry according to the draft of the KADET. If we also check the "Draft CADET" option, all checks are based on the CADET. OBSERVATION: The out-of-plane bending was introduced as an independent option from the CADET in order to give the designer the possibility to include these checks also in case he makes a valuation with EC8-3 (unchecked "Draft CADET)") 2.2.2 In-plane bending and shearing For IN-PLANE COLLAPSE AND STRETCH you have the option to choose to calculate the strengths either according to EC8 part 3) (unchecked "Draft CADET)", or according to CADET. 2.2.3 Bending out of level For OFF-LEVEL checks we always refer to the provisions of the KADET (regardless whether or not the "Draft" is activated). ❖ For Performance Level A, checks in terms of forces 1. At the same time in the horizontal joint Two methods were incorporated to calculate the load-bearing capacity of unreinforced masonry elements in out-of-plane bending: