10D. DIMENSIONING PART 4/4
CHAPTER 10D 'DIMENSIONING' 17 Show reasons for exhaustion with Color Gradation Bearing masonry as in the sizing process has been divided into new and existing (Valuation). All ratios shown in the following illustrations are the corresponding ratios printed in the respective issues ⮚ New masonry building (EC6) 1. Bending within level 2. Bending out of plane parallel to the horizontal joint 3. Bending out of plane perpendicular to the horizontal joint 4. Shear 5. Check for Vertical Loads 6. Looseness check for vertical loads At this point it should be stressed that especially in new masonry the wall is not painted in its entirety. Only the section from which the specific reason is derived is coloured. Let us look at an example where only the following 3 walls have been dimensioned for supervision purposes.