10B. DIMENSIONING PART 2/4

CHAPTER 10B 'DIMENSIONING' 100 ZONE 6 ZONE 6 relates to the ACTIVE OPENING of the section and includes the field of longitudinal reinforcement of the concrete sheathing placed at the top and/or bottom tread of the slab. In the case of reinforcement with IOP or Steel plate, the reinforcement spans are replaced by those of the IOP or Steel plate layers. (α) (β) Pure reinforcement reinforcement overlay with concrete sheathing on the Upper and Lower Tread. Update the graphic depiction of the concrete sheathing reinforcement areas at the Upper and Lower Treads on the section sketch (see ZONE 2). Coordinate of the beginning of the reinforcement area of the concrete mantle. The value is automatically filled in based on the End value of the previous area. Coordinate of the end of the reinforcement area of the concrete jacket. The value shall be less than the total length of the slab opening. Thickness of additional layer of concrete mantle. Diameter of longitudinal reinforcement bars. Distance between the bars.