10A. DIMENSIONING PART 1/4

Ex-post change of beta angle If finally the beta angle is changed afterwards from 0 degrees to 90 degrees (counter-rotation), 0 degrees 90 degrees the dimensioning axes are now twisted by -90 degrees, i.e. they are in the 0 degree state. So the dimensioning torque My(0) is equal to -Mz(90) of the local and the torque Mz(0) sizing is equal to My(90) of local. 0 degrees (sizing) 90 degrees (local axes) My(0)=-Mz(90)= 9.175 =-(-9.175) Mz(0)=My(90)=13.3

RkJQdWJsaXNoZXIy NTIwNzc=