10A. DIMENSIONING PART 1/4

For metals, EC3 is applied through the programme and is included in all scenarios regardless of the fact that there is no corresponding Greek regulation. If you are modifying an existing script, select . In the "Delete Dimensioning" field, activate the corresponding checkbox and "Apply", to delete the results of a previous dimensioning (for concrete elements, steel sections, or connections respectively), to re-dimension using other combinations, or parameters, or scenario, etc. 1.1.1 Storage and import of modified armaments Within the NEO field there is now the possibility to store the total armament of the building as well as to delete in total all the reinforcement of beams and poles . With the Total Building Reinforcement field, it is now possible to store the reinforcement of beams and columns with the manual modifications made by the user in order to adjust the reinforcement of an existing design for the purpose of evaluation and redesign, as well as the reinforcements given to these elements. This command is very useful in cases where the need arises to remove, modify or add a new element. PROCEDURE: In these cases select Save, then return to the modelling, make the modifications to the vector, run the original EC8_Greek analysis (Static or Dynamic) and come back to the dimensioning. You load the combinations again and re-dimension the entire vector to pick up reinforcements and new or modified elements. By selecting the Insert command, all the rebars and any reinforcements that you manually inserted into the pre-existing elements are brought back in. It now remains to insert the existing reinforcements into the new or modified elements.