i.e. a total of 3 (e.g. F16-F18-F20). If you enter the value 0 the program will use only one diameter. The parameters relating to the reinforcement of the wall frame are then specified. For horizontal and vertical bars respectively, you specify the minimum and maximum diameter to be used, as well as the minimum distance below which the diameter will be increased. While minF/cm is a limitation at the square centimetre level on the surface of the trunk. By default you set the ratio to F10/15 horizontally and vertically. In the " Shear " field First we start by defining a LOWER BORDER of reinforcement: is the minimum for the connector reinforcement desired by the designer. If this reinforcement is sufficient, it shall be installed. If the minimum reinforcement we have defined is now not sufficient, then the program searches for the reinforcement required based on intensity and starts with Φmin: and with a distance greater than . If the need for a shorter distance below arises, the diameter is changed up to .