EXAMPLE 7. VALUATION OF A BUILDING FROM LOAD-BEARING MASONRY
EXAMPLE 7: 'VALUATION OF A MASONRY BUILDING' 49 The checks applied are at the cross-sectional level of the pile/floor, where the prevailing intensive magnitude is either: • the axial force and bending, either • the cutting machine The critical failure of the masonry element is therefore obtained and its load-bearing capacity is calculated accordingly for all three performance levels A, B and C. After the process is complete, select the command In the dialog box that opens, you are asked to specify the walls in the same way as described in " New masonry building ". For more convenience when defining the walls, select all layers and make them "Invisible". Then select the "Lines-Circles" layer and press the "Visible" button. In this way, selecting the points for defining the dimensions of the walls with the corresponding picks becomes much easier.