EXAMPLE 7. VALUATION OF A BUILDING FROM LOAD-BEARING MASONRY
EXAMPLE 7: 'VALUATION OF A MASONRY BUILDING' 23 allowing you to modify them, give them another name, change the thickness, or even choose from the library a different wall for that particular face. Finally, press the button to register the modifications. – If a surface is flat you need to activate the checkbox – It is recommended not to define very small surfaces. – When there are consecutive surfaces it is good not to have big differences – in the dimension of the surface element between these successive surfaces. – The ratio of surface element thickness/width of surface element not be disproportionate NEW In the new version of SCADA Pro, we added the Mesh Consolidation, offering multiple new features, such as the ability to import a 2nd dwg ( see User Manual Modeling - § Mesh Consolidation ) The procedure to follow when you have two or more floor contours from different dwg is as follows: ❖ Import the first dwg, ❖ you do, as you know, a face recognition and create the ground floor. ❖ Then you bring in the second dwg, ❖ you identify faces and "glue" the first floor on top of the ground floor. You now have two main groups and lines that are identified and/or need to be broken. Same process for as many floors as I have. Finally, using the "Consolidate" command, you select all the main groups that have been created and create a new one that includes all the subgroups with their outlines now as they should be. If you want, you can now erase the original groups and their outline lines.