EXAMPLE 6. BUILDING VALUATION & REDESIGN STUDY

EXAMPLE 6: "STUDY FOR THE VALUATION AND REDESIGN OF A BUILDING ACCORDING TO THE CANC. 35 F. New data on the structural adequacy of arbitrary buildings, in the context of the implementation of the urban planning law 4495/2017 In the context of the implementation of the Planning Law 4495/2017 , which provides for cases where the existing building, partly or entirely arbitrary, is exempted from the structural adequacy test under certain conditions and cases where the structural adequacy test is required. In cases where structural re-inspection is required, the following procedure shall be followed: A) Determination of the SDS B) Complete geometric survey of the construction on site C) Inspection for damage to structural members. If there are substantial damages (e.g. corrosion of reinforcements, carbonation of concrete, etc.) these are recorded and then the corresponding structural degradation factors are calculated based on the CEQA. D) The following assumptions are made for the mechanical characteristics of the materials according to the selected SDS: - for a satisfactory RMS, we define the values of the mechanical characteristics divided by γf=1,1 - for a high SWD, we define the values of the mechanical characteristics divided by γf=1,0 - for a tolerable SWD, we define the values of the mechanical characteristics ( Annex 3.1 of the CEE ) divided by γf=1,2 and we do the sizing.