EXAMPLE 6. BUILDING VALUATION & REDESIGN STUDY
EXAMPLE 6: "STUDY FOR THE VALUATION AND REDESIGN OF A BUILDING ACCORDING TO THE CANC. 18 GENERAL DESCRIPTION A. Geometry The building under study consists of three floors in the superstructure, a foundation level and a roof slab. The foundation consists of footings and a footing under the elevator core. B. Materials For the construction of all members of the structure, concrete of C20/25 quality has been used, and for the reinforcement, steel of B500C quality. In case that in the existing construction to be checked, quality B and STI materials (old material grades) were used, then they will NOT be imported as they are, but will be adapted to the strengths and individual safety factors of the new materials. C. Regulations Eurocode 8 for seismic loads. Eurocode 2 for dimensioning. Intervention Regulation (CEN.EPE). D. Loading - analysis assumptions - Dynamic Spectral Method with homonymous torsional pairs. The loadings according to the above analysis method in SCADA Pro are as follows: (1) G (permanent)