EXAMPLE 6. BUILDING VALUATION & REDESIGN STUDY

EXAMPLE 6: "STUDY FOR THE VALUATION AND REDESIGN OF A BUILDING ACCORDING TO THE CANC. 104 OBSERVATION: At the bottom of the file, the Sectional Adequacy Check is also displayed only for shear-failing elements. • addition, SCADA Pro incorporates the new check of the KANEPE, included in the latest revision of the KAN.EPE (2 h Revision 2017) and concerns the possibility of slippage due to shear at the base or other accidental cross-sections wall . The check is for pushover only and has been incorporated into the printout of the pushover checks in the corresponding section for intersections: The value is the slip resistance cutting torque VR,SLS and the corresponding paragraph of the UNECE is Annex 7C. Two methods are provided for its calculation. The second one, the alternative (equation C.14), has been incorporated in the program.