EXAMPLE 5. NEW BUILDING DESIGN FROM LOAD-BEARING MASONRY

EXAMPLE 5: 'DESIGN OF A LOAD-BEARING MASONRY BUILDING' 43 6. DIMENSIONING 6.1 Creation of a dimensioning scenario for the inspection of load-bearing masonry structure based on the Eurocode For control of load-bearing masonry structures SCADA Pro incorporates the Eurocode 6 controlsIt is therefore necessary to create a Eurocode-based dimensioning scenario in order to perform the relevant checks via the 'Masonry Control' command. In the " Sizing " module and in the "Scripts" command group select the command to create a Eurocode scenario. Select Type EC6-EC8(3), give it a name and press the New button. with "Active" the new script, select the command . In the dialog box, select from the list the file of combinations you saved previously and . The program calculates the combinations and closes the window by pressing the OK button.