EXAMPLE 5: 'DESIGN OF A LOAD-BEARING MASONRY BUILDING' 36 4. ANALYSIS 4.1 Execution of analysis of a load-bearing masonry structure based on the Eurocode: Once the process of modeling the structure and entering its loads is complete, proceed to Analysis. For the analysis of load-bearing masonry structures, SCADA Pro incorporates the parameters of the Eurocode. It is therefore required to create a Eurocode-based analysis scenario to perform the analysis. Go to the " Analysis " section and from the " Scenarios " command group, select the "New" command to create a Eurocode scenario for the analysis of the load-bearing masonry structure. Select the "New" command and in the dialog box: -select Node Recount with the Cuthill-McKee(II) method -choose from the predefined ones or create a new script by selecting EC-8_Greek Dynamic -press the "Knots" button and release the spring movements (select "Yes")