EXAMPLE 1. NEW BUILDING DESIGN FROM REINFORCED CONCRETE

EXAMPLE 1: 'REINFORCED CONCRETE CONSTRUCTION STUDY' 51 4.4 How to import loads of members: From the " Member loads " field select " Insert " and then select the elements of the member (members, nodes, finite surface) on which the loads will be applied. The selection of these elements can be done in one of the known ways . When the selection is complete, press the right mouse button and the following dialog box appears By selecting the " Insert " button, the defined load is displayed in the table with all its elements and with OK it is applied to the selected members. OBSERVATION: In the new version of the program, by selecting the Edit (Selective or Total) command and a load in the list, all loads belonging to the same load and having the same value are automatically reddened in the 3D representation of the vector.