EXAMPLE 11. MASONRY WITH THE EQUAL FRAME METHOD

PARADEIGMA 11: " MASONRY M.I.P." 21 3.2 EXAMPLE Let's look at an example of one of these results. For a performance level C corresponding to step 32 the form of the failure of the structure is as follows In the parameters we have unchecked the option "Plastic joints at both ends" and so at the ends of some elements there are different kinds of failures like in member 80. In total we have 9 pins that fail but in red we have 9 ends which are all square which means they fail in tension. This is also shown in the summary table